Sanitary Construction: Engineered with crevice-free internal surfaces, non-toxic and non-reactive materials, and smooth polished finishes to prevent bacterial growth, contamination, and product degradation—compliant with global sanitary standards (3A, FDA, EHEDG, ISO 2852, DIN 3357).
Manual Operation: Equipped with a manually operated handle that enables quarter-turn control, allowing for precise, hands-on adjustment of flow direction without the need for external power sources (pneumatic or electric actuators).
High Platform Forgings: The valve body and key components are manufactured using high-platform forging technology, which involves shaping stainless steel under high pressure and temperature to create a dense, uniform structure with superior strength, corrosion resistance, and dimensional accuracy compared to cast components.
Quick Release Connections: Features quick-release fittings (typically tri-clamp/tri-clover) that allow for rapid disassembly and reassembly, facilitating frequent cleaning, maintenance, and equipment changeover—critical for hygienic processes requiring strict contamination control.
Vacuum Compatibility: Designed to withstand vacuum conditions (typically -0.1 MPa to 0 MPa) without leaking or compromising performance, making it suitable for processes such as vacuum drying, vacuum packaging, and sterile processing where low-pressure environments are required.
Sanitary Design: A design philosophy focused on eliminating dead spaces, crevices, and rough surfaces that can harbor bacteria, mold, or media residues. Sanitary valves feature polished internal surfaces (typically Ra ≤ 0.8 μm for internal surfaces and Ra ≤ 1.6 μm for external surfaces) and non-toxic materials to ensure product purity.
Manual Operation: A valve control method that relies on human intervention (via a handle or lever) to rotate the ball and adjust flow direction. Manual valves are simple, cost-effective, and ideal for applications where flow direction changes are infrequent or require hands-on oversight.
High Platform Forging: A metalworking process where stainless steel is heated to a high temperature (typically 1100–1200°C) and shaped under high pressure using a forging press. This process creates a dense, grain-refined structure that is stronger, more corrosion-resistant, and more dimensionally accurate than cast components, making it ideal for high-pressure and vacuum applications.
Quick Release Connections: Fittings (such as tri-clamp, quick-disconnect, or bayonet) that allow for rapid disassembly and reassembly of the valve without the need for specialized tools. This enables efficient cleaning (CIP/SIP) and maintenance, reducing downtime in hygienic processes.
Vacuum Compatibility: The ability of a valve to maintain a leak-tight seal under vacuum conditions (negative pressure). Vacuum-compatible valves are designed with specialized seals, thick-walled construction, and anti-suckback features to prevent air ingress and ensure process integrity.
Three-Way Flow Control: The ability of a valve to regulate flow between three ports (inlet/outlet connections), enabling three primary functions: diverting flow (sending media from one inlet to two outlets), mixing flow (combining media from two inlets into one outlet), or switching flow (alternating media flow between two outlets from a single inlet).
CIP (Clean-in-Place): A method of cleaning sanitary equipment without disassembly, using recirculating cleaning agents (e.g., caustic soda, peracetic acid) to remove residues and bacteria. Sanitary manual high platform forgings quick release three-way vacuum ball valves are designed to be CIP-compatible, with smooth internal surfaces that allow cleaning agents to flow freely.
SIP (Sterilize-in-Place): A process used to sterilize sanitary equipment using steam or high-temperature water, ensuring the complete elimination of bacteria and other microorganisms. These valves must withstand high temperatures (up to 150°C during SIP) without compromising performance or hygiene.
Full-Port Design: A valve design where the ball’s bore is the same diameter as the valve’s ports, creating an unobstructed flow path that minimizes pressure drop, prevents media buildup, and facilitates CIP/SIP processes—critical for vacuum applications where flow efficiency is essential.
L-Port Ball: A three-way ball valve design with a 90-degree L-shaped bore that connects two ports at a time, ideal for diverting or switching flow (e.g., sending media from one inlet to either of two outlets) in vacuum processes.
T-Port Ball: A three-way ball valve design with a T-shaped bore that can connect all three ports simultaneously, ideal for mixing media from two inlets into one outlet or diverting flow to two outlets in vacuum applications.
3A Certification: A certification issued by 3-A Sanitary Standards, Inc., ensuring that sanitary equipment meets strict hygiene and performance standards for food, beverage, and pharmaceutical applications.
FDA Compliance: Compliance with the U.S. Food and Drug Administration (FDA) regulations, ensuring that materials used in the valve are non-toxic, non-reactive, and safe for contact with food, beverages, and pharmaceuticals.
EHEDG Certification: Certification from the European Hygienic Engineering & Design Group (EHEDG), confirming that the valve meets strict hygienic design standards for use in the food, beverage, and pharmaceutical industries.
Vacuum Rating: The maximum negative pressure a valve can withstand without leaking or failing, typically measured in MPa (megapascals) or bar. Sanitary manual high platform forgings quick release three-way vacuum ball valves commonly have vacuum ratings of -0.1 MPa (full vacuum) to 0 MPa.
Feature | Sanitary Manual High Platform Forgings Quick Release Three-Way Vacuum Ball Valve | Standard Sanitary Three-Way Ball Valve |
|---|---|---|
Construction | High platform forging (dense, strong, corrosion-resistant structure); thick-walled design for vacuum resistance | Cast or standard forging (less dense; thinner walls); not optimized for vacuum |
Vacuum Compatibility | Designed to withstand vacuum conditions (-0.1 MPa to 0 MPa); leak-tight seal under negative pressure | Not optimized for vacuum; may leak or fail under negative pressure |
Connections | Quick release (tri-clamp, quick-disconnect) for rapid disassembly/cleaning | May have weld, threaded, or tri-clamp connections; not always quick release |
Strength & Durability | High platform forging provides superior strength, dimensional accuracy, and corrosion resistance | Standard construction (cast/standard forging) offers moderate strength and durability |
Applications | Vacuum processes (vacuum drying, packaging, sterile processing); high-hygiene, high-pressure applications | Standard hygienic processes (mixing, diverting) without vacuum requirements |
Seal Design | Specialized vacuum seals (PTFE, EPDM) to prevent air ingress under negative pressure | Standard sanitary seals; not optimized for vacuum conditions |
Function: Provides a crevice-free housing for the ball and seats, maintains the flow path, and serves as the mounting point for quick release connections. The body’s thick-walled, forged design ensures it can withstand vacuum conditions (-0.1 MPa to 0 MPa) without deformation or leakage. It also facilitates CIP/SIP processes by eliminating dead spaces.
Materials: Typically manufactured from forged stainless steel, with the most common grades being 304 (AISI 1.4301) and 316L (AISI 1.4404). 304 stainless steel is cost-effective and suitable for most hygienic vacuum applications, offering good corrosion resistance to mild cleaning agents and process media. 316L stainless steel is preferred for more demanding applications (e.g., acidic media, aggressive cleaning agents) due to its molybdenum content, which enhances resistance to pitting and crevice corrosion. Both grades are FDA-compliant, non-toxic, and non-reactive.
Design Features: Smooth internal surfaces polished to Ra ≤ 0.8 μm, thick-walled construction (typically 3–5 mm thicker than standard valves) to withstand vacuum pressure, three ports (labeled Port 1, Port 2, Port 3) arranged in a T or L configuration, and integrated quick release connection points (tri-clamp) for easy disassembly. The body is also designed to be CIP/SIP compatible, with no dead spaces or crevices.
Function: Rotates 90 degrees (via the stem and handle) to align its bore with the desired ports, controlling whether media is diverted, mixed, or switched. The ball’s surface presses against the sanitary vacuum seats to create a leak-tight seal when in the closed position for specific ports, preventing air ingress under vacuum.
Materials: Manufactured from forged or machined stainless steel (304 or 316L) to match the valve body, ensuring compatibility and corrosion resistance. The ball is precision-machined and polished to Ra ≤ 0.3 μm to reduce friction with the seats, prevent media adherence, and ensure a tight seal under vacuum. For applications requiring enhanced wear resistance, the ball may be coated with Stellite or tungsten carbide.
Design Features: Full-port bore (same diameter as the valve ports) to minimize pressure drop and prevent media buildup—critical for vacuum applications where flow efficiency is essential. The ball is available in L-port (for diverting/switching) or T-port (for mixing/diverting) configurations, with a keyway or spline connection to the stem for secure rotational force transmission.
Function: Press against the ball’s surface to create a bubble-tight seal when the valve is in specific positions, preventing media leakage and air ingress (critical for vacuum processes). The seats must withstand process media, high temperatures (up to 150°C during SIP), aggressive cleaning agents, and vacuum pressure without compromising performance.
Materials: FDA-compliant soft materials, including PTFE (polytetrafluoroethylene), EPDM (ethylene propylene diene monomer), and FPM (fluoropolymer, e.g., Viton). PTFE is the most common, offering excellent chemical resistance, high temperature tolerance (up to 260°C), and compatibility with vacuum conditions. EPDM is suitable for steam applications, while FPM is ideal for aggressive chemicals. The seats may also feature a spring-loaded design to ensure consistent sealing pressure under vacuum.
Design Features: Crevice-free design to prevent bacterial growth, spring-loaded (optional) to maintain consistent sealing pressure even with wear or temperature changes, and easy to replace for maintenance. The seat design is optimized for vacuum conditions, with a larger contact area to prevent air ingress.
Function: Transmit rotational force from the manual handle to the ball, enabling the valve to rotate 90 degrees and adjust flow direction. The stem also provides a seal to prevent media leakage and air ingress (critical for vacuum processes).
Materials: Forged or machined stainless steel (304 or 316L) to match the valve body and ball. The stem may feature an anti-blowout design (critical for high-pressure and vacuum applications) to prevent accidental dislodgment under pressure. It may also be coated with a corrosion-resistant finish to enhance durability.
Design Features: Precision-machined for smooth rotation, polished surface to reduce friction, and a sanitary stem seal (PTFE or EPDM) to prevent leaks and air ingress. The stem’s length is optimized for easy access, even in tight spaces, and it may feature a keyway to ensure secure connection to the handle and ball.
Function: Allow the user to rotate the stem and ball, adjusting flow direction with a 90-degree quarter-turn. The handle provides a clear visual indicator of the current flow path, reducing human error.
Materials: Manufactured from stainless steel (304 or 316L) with a polished finish for easy cleaning and corrosion resistance. The handle may feature an ergonomic grip to enhance comfort during operation.
Design Features: Ergonomic grip for easy operation, flow direction indicators (e.g., “Port 1→Port 2,” “Port 1→Port 3”) to show the current flow path, and a locking mechanism (optional) to prevent accidental operation. The handle is securely attached to the stem, ensuring reliable force transmission.
Types: The most common quick release connection is the tri-clamp (tri-clover) fitting, which features a quick-release clamp, sanitary gasket, and polished sealing surfaces. Other quick release options include quick-disconnect and bayonet fittings, but tri-clamp is preferred in hygienic applications due to its crevice-free design and ease of use.
Materials: Stainless steel (304 or 316L) to match the valve body, with polished sealing surfaces to prevent bacterial growth. Sanitary gaskets (EPDM, PTFE, or silicone) are used to enhance the seal and ensure leak-tight performance under vacuum.
Design Features: Crevice-free design to prevent bacterial growth, quick-release clamp for easy disassembly (no specialized tools required), and compatibility with standard Sanitary Pipelines. The connection is designed to maintain a leak-tight seal under vacuum conditions, preventing air ingress.
Anti-Suckback Valve: An optional component that prevents media from being sucked back into the pipeline under vacuum, ensuring process integrity and preventing contamination.
Vacuum Gauge Port: A port for attaching a vacuum gauge, allowing operators to monitor the vacuum level within the valve and pipeline, ensuring optimal performance.
Reinforced Seals: Extra-thick or dual seals to provide additional protection against air ingress under high vacuum conditions.
Initial Position (Default Flow Path): In the default position, the L-shaped bore of the ball connects Port 1 (inlet) to Port 2 (outlet), allowing media to flow from Port 1 to Port 2 under vacuum. Port 3 is closed, with the ball’s surface pressing against the seat for Port 3 to create a leak-tight seal, preventing air ingress. The handle is aligned with the Port 1-Port 2 flow path, providing a clear visual indicator.
Switching Flow Direction: To divert flow from Port 1 to Port 3, the user rotates the handle 90 degrees clockwise or counterclockwise (depending on the valve design). This rotational force is transmitted through the stem to the ball, rotating the L-port to connect Port 1 to Port 3. Port 2 is now closed, with the ball’s surface pressing against the seat for Port 2 to maintain a leak-tight seal under vacuum. The handle is now aligned with the Port 1-Port 3 flow path, confirming the new flow direction.
Closing the Valve: To stop all flow and maintain vacuum integrity, the handle can be rotated to a position where the L-port does not connect any two ports (if the valve is designed for this function). In this position, the ball’s surface presses against all three seats, creating a leak-tight seal and stopping media flow entirely while preventing air ingress.
Vacuum Integrity Check: After adjusting the valve position, operators should check the vacuum gauge (if installed) to ensure the vacuum level remains stable (no drop in pressure), indicating a leak-tight seal. If the vacuum level drops, it may indicate a worn seal or improper valve positioning.
Cleaning (CIP/SIP): To clean the valve, the user first closes the valve, isolates it from the pipeline using isolation valves, and releases the vacuum. The quick release connections (tri-clamp) are then disconnected, allowing the valve to be disassembled (if necessary) or cleaned in place. CIP/SIP cleaning agents are circulated through the valve, with the ball rotated to ensure all internal surfaces (including the bore and seats) are exposed to the cleaning agents. The smooth, polished surfaces ensure no residues or bacteria remain after cleaning. After cleaning, the valve is reassembled, and the vacuum is re-established.
Initial Position (Mixing Flow): In the default mixing position, the T-shaped bore of the ball connects Port 1 (inlet 1) and Port 2 (inlet 2) to Port 3 (outlet), allowing two media to mix together as they flow through Port 3 under vacuum. The handle is aligned with the Port 3 outlet, indicating the mixing function. The valve maintains a leak-tight seal to prevent air ingress, ensuring the vacuum level remains stable.
Diverting Flow: To divert flow from Port 1 to both Port 2 and Port 3, the user rotates the handle 90 degrees. This rotates the T-port to connect Port 1 to Port 2 and Port 3, allowing media to flow from Port 1 to both outlets simultaneously under vacuum. This is useful for splitting a single media stream into two process lines while maintaining vacuum integrity.
Single Flow Path: To switch to a single flow path (e.g., Port 1 to Port 3 only), the handle is rotated another 90 degrees, aligning the T-port to connect only Port 1 and Port 3. Port 2 is closed, with the ball’s surface pressing against the seat for Port 2 to prevent air ingress. The handle is aligned with the Port 1-Port 3 flow path, confirming the single flow direction.
Vacuum Integrity Check: After each position adjustment, operators should verify the vacuum level using a gauge to ensure no air ingress. A drop in vacuum pressure may indicate a seal issue or improper valve alignment, which should be addressed immediately to prevent process contamination or inefficiency.
Cleaning (CIP/SIP): Similar to L-port valves, T-port valves are cleaned by first closing the valve, isolating it from the pipeline, and releasing the vacuum. The quick release connections are disconnected, and CIP/SIP agents are circulated through the valve, with the ball rotated to ensure all internal surfaces (including the T-shaped bore) are exposed. The valve is then reassembled, and the vacuum is re-established.
Seal Integrity: The valve’s seats and stem seals must be in good condition to prevent air ingress. Worn or damaged seals can cause vacuum leaks, reducing process efficiency and increasing the risk of contamination. Regular inspection and replacement of seals are critical.
Valve Positioning: Improper valve positioning can create gaps between the ball and seats, allowing air to enter. Operators should ensure the handle is fully rotated to the correct position, with a firm stop to indicate proper alignment.
Material Compatibility: The valve’s materials (body, ball, seals) must be compatible with the process media and cleaning agents to prevent degradation, which can lead to leaks. For example, acidic media may require 316L stainless steel and PTFE seals.
Vacuum Level: The valve’s vacuum rating must match the process’s vacuum requirements. Using a valve with a lower vacuum rating than required can lead to failure or leaks. Most valves are rated for full vacuum (-0.1 MPa), but it is important to verify the rating for specific applications.
Cleaning & Maintenance: Residues or debris on the ball or seats can compromise the seal under vacuum. Thorough CIP/SIP cleaning and regular maintenance (e.g., seat replacement) are essential to maintain vacuum integrity.
Key Features: 90-degree L-shaped bore, full-port design, high platform forged body, quick release (tri-clamp) connections, manual handle with flow indicators, vacuum-compatible seals (PTFE/EPDM), and polished internal surfaces (Ra ≤ 0.8 μm). The valve can only connect two ports at a time, preventing unintended mixing of media and ensuring vacuum integrity.
Advantages: Simple manual operation, leak-tight performance under vacuum, easy cleaning (CIP/SIP compatible), quick disassembly via quick release connections, and ideal for diverting/switching flow in vacuum processes. The L-port design eliminates dead spaces, reducing the risk of contamination.
Applications: Vacuum packaging (diverting product to different packaging lines), vacuum drying (switching between drying chambers), pharmaceutical sterile processing (diverting sterile media), and dairy processing (diverting vacuum-treated milk to storage or processing lines).
Key Features: T-shaped bore, full-port design, high platform forged body, quick release (tri-clamp) connections, manual handle with flow indicators, vacuum-compatible seals, and polished internal surfaces. The valve can connect two inlets to one outlet (mixing) or one inlet to two outlets (diverting) while maintaining vacuum integrity.
Advantages: Versatile flow control (mixing and diverting), leak-tight performance under vacuum, easy cleaning and maintenance, quick disassembly, and compatible with CIP/SIP systems. The T-port design allows for simultaneous flow through multiple ports, improving process efficiency in vacuum applications.
Applications: Vacuum mixing (mixing vacuum-processed ingredients in food production), pharmaceutical compounding (mixing active ingredients under vacuum), biotech cell culture (diverting vacuum-treated media to different bioreactors), and cosmetic manufacturing (mixing oils and water under vacuum).
Key Features: Tri-clamp fitting (stainless steel 304/316L), sanitary gasket (EPDM/PTFE/silicone), quick-release clamp (no specialized tools required), polished sealing surfaces, and crevice-free design. The connection is compatible with standard sanitary pipelines and maintains a leak-tight seal under vacuum.
Advantages: Easy assembly/disassembly, crevice-free design (prevents bacterial growth), compatible with CIP/SIP systems, ideal for frequent cleaning, and standard in sanitary industries—ensuring compatibility with existing equipment. The tri-clamp connection provides a secure seal under vacuum, preventing air ingress.
Applications: Food and beverage, pharmaceutical, dairy, and biotechnology industries—especially in vacuum processes where frequent cleaning or equipment changeover is required (e.g., vacuum packaging, sterile processing).
Key Features: Quick-disconnect coupling (stainless steel 304/316L), sanitary gasket, push-button or lever release mechanism, and polished sealing surfaces. The connection is designed to be leak-tight under vacuum and compatible with CIP/SIP systems.
Advantages: Extremely fast disassembly/assembly, crevice-free design, leak-tight performance under vacuum, and ideal for applications with frequent valve removal (e.g., laboratory equipment, small-scale vacuum processes).
Applications: Laboratory vacuum systems, small-scale pharmaceutical processing, and applications where the valve needs to be quickly swapped between different pipelines.
Key Features: Bayonet coupling (stainless steel 304/316L), sanitary gasket, twisting lock mechanism, and polished sealing surfaces. The connection is designed to withstand high vacuum pressures (-0.1 MPa) without leaking.
Advantages: Secure, leak-tight seal under high vacuum, easy to lock/unlock (twist mechanism), crevice-free design, and compatible with CIP/SIP systems. The bayonet connection is more secure than tri-clamp or quick-disconnect, making it ideal for high-vacuum applications.
Applications: High-vacuum processes such as vacuum freeze-drying, sterile pharmaceutical manufacturing, and biotech applications where vacuum integrity is critical.
Key Features: Designed to withstand vacuum pressures up to -0.08 MPa (80% vacuum), standard thick-walled forging, PTFE/EPDM seals, and quick release connections. Suitable for most general vacuum applications.
Advantages: Cost-effective, reliable performance for standard vacuum processes, easy to maintain, and compatible with CIP/SIP systems.
Applications: Vacuum packaging, vacuum mixing, and general hygienic processes where moderate vacuum levels are required.
Key Features: Designed to withstand high vacuum pressures (up to full vacuum, -0.1 MPa), reinforced thick-walled forging, dual seals, and anti-suckback features. The valve is engineered to prevent air ingress even under extreme negative pressure.
Advantages: Leak-tight performance under high vacuum, durable construction, and suitable for demanding vacuum applications. The dual seals and reinforced design ensure long-term reliability.
Applications: Vacuum freeze-drying, sterile pharmaceutical processing, vacuum distillation, and biotech applications where full vacuum is required.
Key Features: AISI 1.4301 stainless steel high platform forging, polished internal surfaces (Ra ≤ 0.8 μm), FDA-compliant, non-toxic, and non-reactive. 304 stainless steel contains chromium and nickel, offering good corrosion resistance to mild cleaning agents and neutral media.
Advantages: Cost-effective, good corrosion resistance for general applications, easy to polish, compatible with CIP/SIP systems, and suitable for standard vacuum processes. The high platform forging provides superior strength compared to cast 304 valves.
Applications: General hygienic vacuum applications, including food processing (vacuum packaging of baked goods), dairy processing (vacuum treatment of milk), and beverage production (vacuum mixing of juices).
Key Features: AISI 1.4404 stainless steel high platform forging, polished internal surfaces (Ra ≤ 0.8 μm), FDA-compliant, non-toxic, and non-reactive. 316L stainless steel contains molybdenum, enhancing resistance to pitting, crevice corrosion, and acidic media.
Advantages: Superior corrosion resistance to acidic media, aggressive cleaning agents, and high temperatures. The high platform forging provides exceptional strength and durability, making it suitable for demanding vacuum applications. 316L is the preferred material for pharmaceutical and biotech applications.
Applications: Pharmaceutical sterile processing (vacuum handling of acidic active ingredients), food processing (vacuum pickling of acidic foods), biotech cell culture (vacuum-treated media), and cosmetic manufacturing (vacuum mixing of acidic ingredients).
Key Features: Special alloy high platform forging, polished internal surfaces, FDA-compliant, and resistant to extreme conditions (high vacuum, corrosive media, high temperatures).
Advantages: Superior corrosion resistance, high-temperature tolerance (up to 200°C), and durability in harsh vacuum environments. Ideal for applications where standard stainless steel valves would degrade.
Applications: Biotech (corrosive cell culture media under vacuum), pharmaceutical manufacturing (highly acidic or alkaline processes under vacuum), and specialty food processing (highly corrosive ingredients in vacuum applications).
Component | Common Materials | Material Grades/Types | Key Properties | Vacuum Application Suitability |
|---|---|---|---|---|
Valve Body | High Platform Forged Stainless Steel | 304 (AISI 1.4301), 316L (AISI 1.4404), Hastelloy (Special Applications) | Corrosion-resistant, non-toxic, non-reactive, polished internal surfaces (Ra ≤ 0.8 μm), thick-walled (3–5 mm), crevice-free, withstands vacuum (-0.1 MPa) and high temperatures (up to 150°C) | 304: Standard vacuum applications; 316L: Demanding vacuum applications (acidic media); Hastelloy: Extreme vacuum/corrosion conditions |
Spherical Ball | Forged/Machined Stainless Steel | 304 (AISI 1.4301), 316L (AISI 1.4404), Stellite-Coated 316L | Precision-machined, high polish (Ra ≤ 0.3 μm), corrosion-resistant, smooth rotation, full-port design, wear-resistant (Stellite-coated), leak-tight seal under vacuum | All vacuum applications; Stellite-coated for frequent use/abrasive media in vacuum |
Sanitary Vacuum Seats | FDA-Compliant Soft Materials | PTFE, EPDM, FPM (Viton), Silicone | Chemical-resistant, temperature-resistant (up to 260°C for PTFE), non-toxic, non-reactive, leak-tight under vacuum, spring-loaded (optional), crevice-free | PTFE: General vacuum use; EPDM: Steam/vacuum applications; FPM: Aggressive chemicals/vacuum; Silicone: Sterile vacuum applications |
Stem | Forged/Machined Stainless Steel | 304 (AISI 1.4301), 316L (AISI 1.4404) | Corrosion-resistant, high strength, smooth rotation, anti-blowout design, polished surface, sanitary stem seal (prevents air ingress under vacuum) | All vacuum applications; anti-blowout design critical for high-vacuum applications |
Manual Handle | Stainless Steel | 304 (AISI 1.4301), 316L (AISI 1.4404) | Durable, corrosion-resistant, ergonomic grip, flow direction indicators, polished for easy cleaning | All vacuum applications; easy operation critical for vacuum process adjustments |
Quick Release Connections | Stainless Steel + Sanitary Gaskets | 304/316L Stainless Steel (Tri-Clamp/Quick-Disconnect/Bayonet); Gaskets: EPDM/PTFE/Silicone | Crevice-free, leak-tight under vacuum, easy to clean, compatible with CIP/SIP, standard compliance (DIN 3357, ISO 2852) | Tri-Clamp: Frequent cleaning/vacuum; Quick-Disconnect: Frequent valve removal; Bayonet: High-vacuum applications |
Vacuum Gauge Port (Optional) | Stainless Steel | 304 (AISI 1.4301), 316L (AISI 1.4404) |
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.