In industrial valve selection, pressure ratings and standards systems are the foundation for ensuring valve-system compatibility. Different regions and industries use different pressure designation methods—the American standard uses the Class system, while the European standard uses the PN system. Selection must compare within the same system to avoid confusion.
This guide systematically reviews the core concepts of valve pressure ratings, the Class-PN comparison, the major standards systems (ASME, API, ISO, GB) and their applicable scopes, providing engineers with a complete reference framework.

A pressure rating is the maximum allowable working pressure that a valve can withstand at a specified temperature. It is not a fixed value but a temperature-dependent variable—as temperature increases, the allowable pressure decreases.
| Concept | Description |
|---|---|
| Design pressure | Maximum operating pressure determined during system design |
| Operating pressure | Actual pressure during normal system operation |
| Pressure rating (Class/PN) | Standardised designation of a valve's pressure capacity |
| Pressure-temperature rating | Maximum allowable working pressure at different temperatures |
| System | Standard | Reference Temperature | Typical Designation |
|---|---|---|---|
| American (Class) | ASME B16.34 | Approximately 38°C (100°F) | Class 150, Class 300, Class 600 |
| European (PN) | EN 1092-1 / ISO 7005 | Ambient (20°C or 120°C) | PN16, PN25, PN40, PN100 |
Key understanding:
Class indicates a rating level rather than a specific pressure value—Class 150 does not equal 150 psi; its actual working pressure at ambient temperature is approximately 285 psi
PN indicates an approximate pressure value in bar—PN16 is approximately 16 bar
The reference temperatures differ between the two systems; direct comparison requires reference to standard conversion tables
| Class | PN (bar) | Nominal Pressure (MPa) | Approx. Working Pressure (bar) |
|---|---|---|---|
| Class 150 | PN 20 | 2.0 | 19.6 |
| Class 300 | PN 50 | 5.0 | 51.1 |
| Class 400 | PN 64 | 6.4 | 68.9 |
| Class 600 | PN 100 | 10.0 | 103.4 |
| Class 900 | PN 150 | 15.0 | 155.1 |
| Class 1500 | PN 260 | 26.0 | 258.6 |
| Class 2500 | PN 420 | 42.0 | 430.9 |
Note: The above table shows approximate comparisons at ambient temperature. For actual selection, the pressure-temperature rating tables in the relevant standards should be consulted based on operating temperature.
Using ASME B16.34 as an example, the maximum allowable working pressure for a Class 300 valve at different temperatures:
| Temperature (°C) | Class 300 Maximum Allowable Pressure (bar) |
|---|---|
| 38°C | 51.1 |
| 100°C | 47.5 |
| 200°C | 41.9 |
| 300°C | 36.1 |
| 400°C | 31.0 |
| 500°C | 23.1 |
Key principle: Selection must simultaneously confirm that both operating pressure and temperature fall within the valve's rated range—judgment cannot be based solely on ambient temperature pressure ratings.
| Standards System | Key Standards | Applicable Scope | Typical Representation |
|---|---|---|---|
| ASME (American) | ASME B16.34, B16.5, B16.10 | Pressure-temperature ratings, flange dimensions, end-to-end dimensions | North America and globally widespread |
| API (American Petroleum Institute) | API 6D, API 608, API 599, API 598 | Pipeline valves, inspection and testing | Oil and gas industry |
| ISO (International) | ISO 17292, ISO 10434, ISO 4126 | Metal valves, safety devices | International trade |
| EN (European) | EN 1092, EN 12516, EN 1983 | Flanged connections, valve design | Europe and Middle East |
| GB (Chinese) | GB/T 12224, GB/T 9124, GB/T 19672 | Valve design, flanges, pipeline valves | Chinese market |
| JIS (Japanese) | JIS B2071, JIS B2238 | Valve pressure ratings, flanges | Japan and Asia-Pacific |
ASME B16.34 is the foundation standard for valve pressure-temperature ratings, with other standards building upon it.
| Standard | Content |
|---|---|
| ASME B16.34 | Valve pressure-temperature ratings, materials, design, testing (core standard) |
| ASME B16.5 | Pipe flanges and flanged fittings (dimensions, pressure ratings) |
| ASME B16.10 | Face-to-face and end-to-end dimensions of valves |
| ASME B16.47 | Large diameter flanges (NPS 26-60) |
Engineering note: American standard valves are typically marked with Class (e.g., Class 150), while European and Chinese standards typically mark PN (e.g., PN16). Selection must be compared within the same standard system and cannot be converted directly.
API standards primarily target the oil and gas industry, with stricter requirements.
| Standard | Content | Applicable Valve Types |
|---|---|---|
| API 6D | Pipeline valve specification | Ball, gate, plug, check valves |
| API 608 | Metal ball valves | Ball valves |
| API 599 | Metal plug valves | Plug valves |
| API 598 | Valve inspection and testing (general) | All types |
| API 607 / 6FA | Fire testing | Fire-safe design valves |
ISO standards promote unified valve specifications in international trade.
| Standard | Content |
|---|---|
| ISO 17292 | Metal ball valves for petroleum, petrochemical and allied industries |
| ISO 10434 | Gate valves for petroleum and natural gas industries |
| ISO 4126 | Safety devices for protection against excessive pressure |
| ISO 5208 | Valve pressure testing |
European standards define the PN pressure rating system in the EN 1092 flange standard.
| Standard | Content |
|---|---|
| EN 1092-1 | Flanges and their joints – Flange pressure ratings (PN) |
| EN 12516 | Industrial valves – Shell strength |
| EN 1983 | Industrial valves – Material requirements |
| Standard | Content |
|---|---|
| GB/T 12224 | General requirements for steel valves |
| GB/T 9124 | Steel pipe flanges – Pressure-temperature ratings |
| GB/T 19672 | Pipeline valves |
| GB/T 13927 | Industrial valve pressure testing |
For the same pressure rating (e.g., Class 300), different body materials have different allowable working pressures:
| Body Material | ASTM Specification | Allowable Pressure at 38°C (Class 300) |
|---|---|---|
| Carbon steel | A216 WCB | 51.1 bar |
| Stainless steel | A351 CF8M | 51.1 bar |
| Alloy steel | A217 WC6 | 51.1 bar |
| Cast iron | A126 | Lower (not recommended for high pressure) |
Important note: For the same Class, the chemical composition and heat treatment of the material directly affect the pressure-temperature rating. Valve material certificates (MTR) must be verified against actual operating conditions.
ASME B16.34 groups materials by mechanical properties into material groups. Materials within the same group share the same pressure-temperature ratings.
In the food, beverage and pharmaceutical industries, valves must not only meet pressure rating requirements but also comply with hygienic design standards.
| Standard | Applicable Scope | Core Content |
|---|---|---|
| 3-A Sanitary Standards | US dairy, food, pharmaceutical | Hygienic design, cleanability |
| EHEDG | European food, pharmaceutical | Hygienic engineering and design certification |
| ASME BPE | Biopharmaceutical | Materials, surface finish, welding, validation |
| FDA 21 CFR | US food and drug contact materials | Material compliance |
Sanitary valves follow the same Class/PN pressure rating system. For example, sanitary ball valves typically offer Class 150 or PN16 ratings, suitable for most food and pharmaceutical processes.
Related reading: For detailed selection guidance on sanitary ball valves, please refer to Part 2 of this series, How to Select a Sanitary Ball Valve Supplier. That article provides in-depth coverage of full-port design, 3-A certification, CIP/SIP compatibility, and FDA-compliant materials. For sanitary applications requiring fast shut-off and low residue, the Sanitary Ball Valve is the preferred solution—its full-port design ensures zero pressure drop and unobstructed CIP cleaning fluid flow.
The pressure rating of flanged connections must match the valve's pressure rating:
| Flange Standard | Applicable Pressure Ratings | Description |
|---|---|---|
| ASME B16.5 | Class 150, 300, 600, 900, 1500, 2500 | NPS ½-24 |
| ASME B16.47 | Class 150, 300, 600, 900 | NPS 26-60 |
| EN 1092-1 | PN 2.5 - PN 400 | European standard flanges |
| GB/T 9124 | PN 2.5 - PN 420 | Chinese standard flanges |
| Mistake | Correct Practice |
|---|---|
| Assuming Class 150 = 150 psi | Class 150 is approximately 285 psi at ambient temperature—consult pressure-temperature rating tables |
| Ignoring temperature's effect on pressure rating | As temperature rises, allowable pressure decreases—must select based on actual operating temperature |
| Directly converting between different standard systems | Class and PN flange dimensions differ—must confirm flange standard compatibility |
| Selecting sanitary valves solely by pressure rating | Must also verify hygienic certifications (3-A, EHEDG, FDA) |
| Not verifying valve material certificates | Non-compliant materials may fail to meet pressure-temperature ratings |
| Application Region | Recommended Standards System | Reason |
|---|---|---|
| North American market | ASME + API | Local standards, wide supplier base |
| European market | EN + ISO | Local standards, regulatory requirements |
| Middle East market | API + ISO | Oil and gas dominated |
| Chinese market | GB + ASME | GB mandatory, ASME widely accepted |
| International trade | ASME + ISO | Highest global recognition |
← Previous article: Valve Actuator Selection Guide: Manual/Pneumatic/Electric/Hydraulic – Torque Calculation and Sizing
→ Next article: Industrial Valve Material Selection Guide: Carbon Steel / Stainless Steel / Alloy / Special Materials