In the food, dairy, beverage, pharmaceutical and biotech industries, CIP (Clean‑in‑Place) and SIP (Sterilisation‑in‑Place) are core processes for ensuring equipment hygiene and sterility. CIP systems use circulating cleaning solutions (acids, alkalis, hot water) to remove residues from internal surfaces; SIP systems use saturated steam or superheated water to sterilise equipment.
Valves play a critical role in CIP/SIP systems – they control the flow of cleaning solutions and steam, isolate different zones, prevent cross‑contamination, and drain condensate during sterilisation. Incorrect valve selection or configuration can lead to cleaning dead legs, incomplete sterilisation, leaks or even batch failures.
This guide provides engineers with a complete valve configuration and selection framework covering CIP/SIP principles, valve type selection, configuration schemes, material and certification requirements, and common mistakes.

CIP is a method of cleaning pipelines, tanks and process equipment without disassembly. A typical CIP cycle consists of:
| Stage | Medium | Temperature | Time | Purpose |
|---|---|---|---|---|
| Pre‑rinse | Water (ambient) | 20–30°C | 5–10 min | Remove large particles |
| Alkaline wash | NaOH (1–3%) | 70–85°C | 20–40 min | Remove organic matter and proteins |
| Intermediate rinse | Water | Ambient | 5–10 min | Remove alkaline residue |
| Acid wash | HNO₃ or H₃PO₄ (0.5–2%) | 60–80°C | 15–25 min | Remove mineral deposits (scale) |
| Final rinse | Water (purified) | Ambient | 5–10 min | Remove all chemical residues |
| Drying (optional) | Hot air or nitrogen | – | – | Prevent microbial growth |
SIP uses saturated steam to sterilise internal surfaces of equipment, typically used in pharmaceutical, biotech and aseptic food production lines. A typical SIP cycle consists of:
| Stage | Medium | Temperature | Time | Purpose |
|---|---|---|---|---|
| Drain | – | – | – | Drain liquid from equipment |
| Heat‑up | Steam | Heat to 121°C | 5–15 min | Heat equipment to sterilisation temperature |
| Hold | Steam | 121–125°C | 15–30 min | Maintain sterilisation temperature |
| Exhaust/cool | Cooling water or air | Cool to ambient | 10–20 min | Cool to safe temperature |
✅ Critical requirement: Condensate must be continuously drained during SIP. Accumulated condensate lowers the sterilisation temperature and causes sterilisation failure. Therefore, low‑point steam traps are an indispensable component of any SIP system.
The CIP/SIP environment demands far more from valves than standard processes:
| Requirement | Description | Recommended Valves |
|---|---|---|
| Chemical resistance | Withstand NaOH (up to 3%), HNO₃ (up to 2%) and hot water | SS316L, PTFE/EPDM seals |
| High temperature resistance | CIP up to 85°C; SIP up to 150°C (steam) | Stainless steel body, PTFE or EPDM seals |
| Dead‑leg‑free | Avoid areas that cleaning solutions or steam cannot reach | Diaphragm valves, specially designed butterfly valves |
| Drainability | Valves must drain completely after installation, no pooling | Angled installation, low‑point drains |
| High cycle resistance | CIP/SIP systems may cycle many times per day | Pneumatic actuators, high‑cycle‑life seals |
| Surface finish | Internal surface Ra ≤ 0.8 μm to prevent biofilm | Mechanical polish + electropolish |
| Certifications | 3‑A, EHEDG, ASME BPE | Diaphragm valves, butterfly valves |
Features:
Completely dead‑leg‑free; fluid contacts only the body and diaphragm
Diaphragm isolates fluid from the actuator
Suitable for both CIP and SIP
PTFE/EPDM composite diaphragm withstands steam sterilisation
Applications in CIP/SIP:
Tank inlet/outlet isolation
Aseptic boundary valves
Low‑point drains in SIP circuits
Point‑of‑use valves in WFI systems
| Advantages | Disadvantages |
|---|---|
| Dead‑leg‑free, fully drainable | Higher pressure drop (weir type) |
| Suitable for SIP (diaphragm withstands 150°C) | Diaphragm requires periodic replacement (1-2 years) |
| Long leak path, high safety | Higher cost |
Features:
Compact, lightweight
Low pressure drop, suitable for high flow rates
Concentric type suitable for CIP; double‑offset type withstands higher temperatures
Applications in CIP/SIP:
CIP supply and return main lines
High‑flow switching (e.g., CIP supply to multiple tanks)
Not suitable for SIP (seals age quickly)
| Advantages | Disadvantages |
|---|---|
| Low pressure drop, ideal for high flow | Not suitable for SIP (seals不耐蒸汽) |
| Lower cost | Minor dead leg possible at seat‑disc interface |
| Fast operation | – |
Features:
Lowest pressure drop when full‑port
Good sealing performance
According to 3‑A 68‑01, ball valves are COP only (clean‑out‑of‑place)
Applications in CIP/SIP:
Not recommended for CIP systems (per 3‑A 68‑01)
If used, must be disassembled for COP cleaning
Not suitable for SIP
| Advantages | Disadvantages |
|---|---|
| Lowest pressure drop | Not suitable for CIP (3‑A 68‑01 restriction) |
| Good sealing performance | Cavity dead leg exists (even if filled) |
| Long service life | Not suitable for SIP |
⚠ Important note (2023 3‑A 68‑01 standard update): Ball valves are explicitly classified as COP only and are no longer considered suitable for CIP systems. If you use ball valves in a CIP circuit and require 3‑A compliance, the valve must be disassembled for COP cleaning.
Features:
Prevents backflow of cleaning solutions
Spring‑loaded or swing type
Applications in CIP/SIP:
CIP supply pump discharge
Prevents CIP solution from flowing back into the cleaning tank
Prevents cross‑contamination between different tanks
Features:
Automatically drains condensate while preventing steam passage
Thermostatic, thermodynamic or float types
Applications in CIP/SIP:
Installed at low points of pipelines and equipment during SIP
Drains steam condensate to ensure sterilisation temperature
An indispensable component of any SIP system
| Type | Application | Advantages | Disadvantages |
|---|---|---|---|
| Thermostatic | Low‑pressure steam | Compact, low cost | Large sub‑cooling |
| Thermodynamic | Medium‑high pressure steam | Durable, water‑hammer resistant | Intermittent operation, may leak steam |
| Float | Large condensate loads | Continuous discharge, efficient | Large size, high cost |
Features:
For aseptic sampling
Can be steam‑sterilised in‑place
Applications in CIP/SIP:
Sample to verify sterility after SIP, before production
Aseptic sampling points on tanks and pipelines

The simplest CIP configuration: one cleaning tank, one supply pump, one return pump, one or more process tanks.
| Location | Recommended Valve | Quantity | Notes |
|---|---|---|---|
| CIP supply pump discharge | Butterfly or diaphragm | 1 | Isolate supply circuit |
| CIP return pump suction | Butterfly or diaphragm | 1 | Isolate return circuit |
| Supply main line | Butterfly | As needed | Low pressure drop, high flow |
| Return main line | Butterfly | As needed | Low pressure drop, high flow |
| Process tank inlet | Diaphragm | 1/tank | Dead‑leg‑free isolation |
| Process tank outlet | Diaphragm | 1/tank | Dead‑leg‑free isolation |
| Cleaning solution drain | Diaphragm or ball | 1 | For COP cleaning when disassembled |
Multiple process tanks share one CIP system, switched by valves to clean one tank at a time.
| Location | Recommended Valve | Quantity | Notes |
|---|---|---|---|
| Each tank supply branch | Diaphragm or butterfly | 1/tank | Isolate non‑cleaning tanks |
| Each tank return branch | Diaphragm or butterfly | 1/tank | Isolate non‑cleaning tanks |
| Main supply valve | Butterfly | 1 | System main isolation |
| Main return valve | Butterfly | 1 | System main isolation |
| Location | Recommended Valve | Quantity | Notes |
|---|---|---|---|
| Steam inlet | Diaphragm | 1 | PTFE/EPDM composite diaphragm recommended |
| Before/after steam filter | Diaphragm | 2 | For filter replacement |
| Pipeline low points | Steam trap + upstream diaphragm | As needed | Drain condensate |
| Tank bottom | Diaphragm + steam trap | 1 | Drain condensate |
| Tank top/vent | Diaphragm | 1 | Vent/vacuum break |
| Aseptic vent | Diaphragm + steam trap | 1 | Drain cold air during sterilisation |
| Point‑of‑use (WFI) | Diaphragm | 1/point | Dead‑leg‑free design |
| Material | Suitability | Recommendation |
|---|---|---|
| SS304 | General CIP (non‑aggressive cleaning solutions) | Acceptable |
| SS316L | CIP (acids/alkalis) and SIP (steam) | Strongly recommended |
| Duplex stainless steel | High‑chloride environments (e.g., seawater CIP) | Special cases |
✅ CIP/SIP standard material: SS316L, with its excellent acid/alkali and high‑temperature resistance, is the standard choice for CIP/SIP systems.
| Seal Material | CIP Suitability | SIP Suitability | Notes |
|---|---|---|---|
| EPDM | ✅ Excellent (alkali‑resistant, hot water) | ⚠ Moderate (max 130°C) | Preferred for CIP only |
| PTFE | ✅ Excellent (acid/alkali‑resistant) | ✅ Excellent (to 180°C) | Preferred for SIP, but less elastic |
| PTFE/EPDM composite | ✅ Excellent | ✅ Excellent | Best choice for CIP+SIP |
| FKM | ⚠ Moderate (not alkali‑resistant) | ✅ Excellent (to 200°C) | Not recommended for alkaline CIP |
| Silicone | ⚠ Moderate (not strong alkali‑resistant) | ✅ Excellent (to 150°C) | Common in biopharma |
✅ CIP/SIP seal material recommendations:
CIP only: EPDM
CIP+SIP: PTFE/EPDM composite diaphragm (for diaphragm valves) or PTFE seats (for butterfly valves)
| Application | Recommended Surface Finish | Treatment |
|---|---|---|
| General CIP | Ra ≤ 0.8 μm | Mechanical polish |
| Pharmaceutical CIP | Ra ≤ 0.6 μm | Mechanical polish |
| SIP + aseptic processes | Ra ≤ 0.4 μm | Mechanical polish + electropolish (ASME BPE) |
| System | Valve Location | Recommended Valve Type | Recommended Body/Seal | Actuator |
|---|---|---|---|---|
| CIP | Supply/return main lines | Butterfly (concentric) | SS316L / EPDM | Pneumatic |
| CIP | Tank inlet/outlet | Diaphragm (weir) | SS316L / EPDM | Pneumatic (spring‑return) |
| CIP | Pump discharge | Check + Butterfly | SS316L / EPDM | – |
| CIP | Cleaning solution drain | Diaphragm | SS316L / EPDM | Manual or pneumatic |
| SIP | Steam inlet | Diaphragm (weir) | SS316L / PTFE/EPDM | Pneumatic (spring‑return) |
| SIP | Pipeline low points | Diaphragm + Steam trap | SS316L / PTFE/EPDM | Manual or pneumatic |
| SIP | Tank bottom | Diaphragm + Steam trap | SS316L / PTFE/EPDM | Manual or pneumatic |
| SIP | Aseptic vent | Diaphragm | SS316L / PTFE/EPDM | Manual or pneumatic |
| WFI | Point‑of‑use | Diaphragm (weir) | SS316L electropolished / PTFE | Manual or pneumatic |
| Incorrect Configuration | Consequence | Solution |
|---|---|---|
| Using ball valves in CIP circuits | Cleaning dead legs, non‑compliant with 3‑A | Replace with butterfly or diaphragm valves |
| No low‑point steam trap in SIP system | Condensate accumulation, insufficient sterilisation temperature | Install steam traps at pipeline and equipment low points |
| Using steam‑不耐 seal materials (e.g., standard EPDM) | Seal ageing and leakage | Use PTFE/EPDM composite or full PTFE seals |
| Horizontally mounted valves leading to pooling | Cleaning/sterilisation dead legs | Install valves at an angle or vertically |
| CIP supply and return not isolated | Cleaning solution short‑circuit, tank not cleaned | Install isolation valves on supply and return lines |
| Using standard ball valves as aseptic boundary | Cavity dead leg, sterility cannot be guaranteed | Replace with diaphragm valves |
| Condensate not drained after SIP | Pooled water in tank, microbial growth | Install low‑point steam traps or manual drain valves |
| Maintenance Item | Frequency | Inspection Points |
|---|---|---|
| Diaphragm valve diaphragm | Every 1-2 years | Cracks, hardening, permanent deformation |
| Butterfly valve seat | Every 2-3 years | Wear, cracks, loss of elasticity |
| Steam trap | Every 6-12 months | Blockage, steam leakage |
| Pneumatic actuator seals | Every 3-5 years | Leaks, slow operation |
| Surface finish | Annually | Scratches, corrosion points |
| Pressure test | Annually | Leakage when valve closed |
At Engineering Plumbing, we provide complete valve solutions for CIP/SIP systems:
Diaphragm valves: Weir and straight‑through, DN8–DN100, PTFE/EPDM composite diaphragms, suitable for CIP+SIP
Butterfly valves: Concentric and double‑offset, DN25–DN300, EPDM or PTFE seats
Ball valves: For COP applications only, 3‑A certified (COP only)
Check valves: Spring‑loaded, SS316L, EPDM seals
Steam traps: Thermostatic, thermodynamic, float types – suitable for SIP systems
Material: SS316L with full material test reports (MTRs) and traceability
Surface finish: Mechanical polish Ra ≤ 0.8 μm, electropolish Ra ≤ 0.4 μm (ASME BPE)
Actuators: Pneumatic (spring‑return/double acting), IP67, ATEX optional
Certifications: 3‑A and EHEDG support, complete validation documentation package
📞 CIP/SIP Valve Configuration Consultation
Send your system parameters (number of tanks, pipe sizes, CIP/SIP frequency, cleaning solution types, sterilisation temperature) to our engineering team. We will reply with a complete valve configuration proposal and CAD drawings within 48 hours.
| Requirement | CIP | SIP |
|---|---|---|
| Maximum temperature | 85°C | 150°C (steam) |
| Chemical resistance | Required (acids, alkalis) | Not required (steam) |
| Dead‑leg‑free | Important | Critical |
| Drainability | Important | Critical |
| Steam trap | Not required | Required |
| Recommended valves | Butterfly, diaphragm | Diaphragm |
According to the 2023 update of 3‑A Standard 68‑01, ball valves are explicitly classified as COP only (clean‑out‑of‑place) because their internal cavities create cleaning dead legs that cannot be reached by CIP. Ball valves not marked “COP only” are no longer eligible for 3‑A certification.
CIP only: EPDM is sufficient and lower cost
CIP+SIP: Must use PTFE/EPDM composite diaphragm – the PTFE layer provides high‑temperature and chemical resistance, while the EPDM layer provides elasticity
When steam condenses on pipeline and equipment surfaces, it releases latent heat, but the condensate itself is at a lower temperature than saturated steam. If condensate is not drained promptly, it accumulates at low points, causing the temperature in those areas to drop below the sterilisation temperature, resulting in sterilisation failure. Steam traps automatically drain condensate while preventing steam passage.
Under normal SIP cycles (1-2 cycles per day, 121°C), PTFE/EPDM composite diaphragms typically last 2-3 years or 200,000 cycles. A preventative maintenance schedule with regular diaphragm replacement is recommended.
EPDM: Most common, alkali‑resistant and hot water‑resistant, low cost
PTFE: Resists strong acids and high temperatures, but less elastic – sealing performance not as good as EPDM
EPDM+PTFE composite: Balances chemical resistance and sealing performance
Yes. Our diaphragm and butterfly valves can meet ASME BPE requirements, including material traceability, surface finish (electropolish Ra ≤ 0.4 μm), welder certification and complete documentation packages.
Smooth surfaces reduce microbial adhesion and biofilm formation. Ra ≤ 0.8 μm is required by 3‑A and EHEDG hygienic standards; for aseptic processes, Ra ≤ 0.4 μm (electropolished) is recommended by ASME BPE.