The power generation industry is the second largest consumer of industrial valves, accounting for approximately 21% of the global valve market. Valves in thermal, nuclear, and gas-fired power plants face the most demanding conditions in industrial processing—ultra-high temperatures (up to 650°C), ultra-high pressures (up to 45MPa), large pressure differentials, frequent load fluctuations, and continuous risks of steam erosion and cavitation. In critical positions, a single valve failure can directly lead to unplanned unit shutdowns or even safety incidents.
This guide provides engineers in the power industry with a systematic reference for valve selection, covering typical power system operating conditions, valve configurations at key locations, material and structural selection points, and relevant standards systems.

Power generation is characterized by continuous operation, frequent load fluctuations, and strict regulatory requirements. Valve selection must first be based on actual site operating conditions to avoid risks from parameter mismatches.
| Operating Characteristic | Specific Manifestation | Impact on Valves |
|---|---|---|
| High temperature | Main steam temperature up to 540-630°C | Material creep, sealing surface oxidation, packing aging |
| High pressure | Main steam pressure up to 16-45MPa | Body strength, sealing pressure, self-sealing requirements |
| Large pressure differential | Severe pressure changes during start/stop | Cavitation, flashing, erosion wear |
| Load fluctuation | Frequent start/stop and load adjustment | Thermal cycle fatigue, sealing surface wear |
| Continuous operation | Over 8,000 operating hours per year | Long-term reliability, low maintenance requirements |
Power industry valves follow specialized standards systems:
| Standard | Title | Applicable Scope |
|---|---|---|
| DL/T 1536-2025 | Guide for selection of power plant control valves | Thermal power plant steam/water control valves, ≤45MPa, ≤630°C |
| JB/T 3595 | Technical conditions for power station valves | Power station specific valves |
| E101 | Power plant valve standards | American standard power plant valves |
| ASME B16.34 | Valve pressure-temperature ratings | General valves |
| API 6D | Pipeline valves | Plant external pipelines |
The main steam system operates at the highest temperature and pressure in the power plant, imposing the most stringent requirements on valves.
| Parameter | Typical Value |
|---|---|
| Operating temperature | 540-650°C (ultra-supercritical units) |
| Operating pressure | 16-45MPa (per DL/T 1536-2025) |
Key valve types:
| Valve Location | Recommended Valve Type | Key Requirements |
|---|---|---|
| Main steam isolation | Gate valve | Pressure self-sealing, hard-faced seat and disc |
| Steam bypass | Desuperheating control valve | Thermal shock resistance, fast response (≤1 sec), high precision |
| Steam control | Cage-type control valve | Withstands 566°C, anti-cavitation design, SIL3 capable |
Main steam gate valve features: Uses pressure self-sealing design (sealing improves with higher pressure), seat and disc sealing surfaces typically plasma spray-welded with cobalt-based hard alloy, valve stem treated with anti-corrosion nitriding.
The boiler feedwater system involves large pressure differential regulation and cavitation protection, making it the area with the highest concentration of control valves.
| Valve Location | Recommended Valve Type | Key Requirements |
|---|---|---|
| Boiler feedwater control | Cage-type control valve | Anti-cavitation structure, high closure class, fail-close |
| Feed pump minimum flow recirculation | Multi-stage pressure reducing control valve | Anti-cavitation, anti-clogging, fail-open |
| HP heater/LP heater drain | Drain valve | Anti-flashing, anti-erosion, unobstructed flow path |
Feedwater control valve cavitation: During start/stop phases, feedwater control valves face large pressure differentials and are susceptible to cavitation. Selection should choose multi-stage pressure reducing or labyrinth-structured control valves with anti-cavitation trim materials.
The cooling water system has the largest diameter and highest valve count in the power plant.
| Valve Location | Recommended Valve Type | Key Requirements |
|---|---|---|
| Circulating water inlet/outlet | Butterfly valve (metal-seated) | Large diameter, low flow resistance, seawater/freshwater corrosion resistance |
| Cooling tower piping | Butterfly valve | Fast operation, easy maintenance |
Cooling water system valve features: Metal-seated butterfly valves are the standard configuration—low flow resistance, easy operation, suitable for large-diameter piping. For seawater cooling systems, body material should be duplex stainless steel or nickel-aluminium bronze for seawater corrosion resistance.
| Valve Location | Recommended Valve Type | Key Requirements |
|---|---|---|
| Boiler blowdown | Globe valve | High temperature resistance, erosion resistance |
| Desuperheating | Desuperheating valve | Thermal shock resistance, noise reduction, fast response |
| Flue gas system | Butterfly valve | High temperature resistance (up to 600°C+) |
| Temperature Range | Recommended Body Material | Typical Grade | Applications |
|---|---|---|---|
| ≤425°C | Carbon steel | WCB | Feedwater, cooling water |
| 425-540°C | Chrome-moly steel | WC6 (1.7335) | Main steam, reheat steam |
| 540-600°C | Chrome-moly steel | WC9 (1.7715) | Supercritical main steam |
| 600-650°C | High-temperature alloy steel | 1.4903 | Ultra-supercritical (most demanding) |
Power plant valve sealing surfaces typically use hard alloy overlay welding to withstand high-temperature steam erosion and wear:
| Sealing Surface Material | Hardness | Max Temperature | Typical Application |
|---|---|---|---|
| Cobalt-based hard alloy | High | ≤650°C | Main steam gate, globe valves |
| Stellite 6 | RC 38-48 | ≤650°C | High-temperature high-pressure gate valve sealing surfaces |
High-pressure power plant valves commonly use pressure self-sealing design—the higher the operating pressure, the more reliable the seal.
| Sealing Design | Operating Principle | Applicable Pressure |
|---|---|---|
| Pressure self-sealing bonnet | Media pressure compresses sealing ring | ≥Class 900 |
| Flexible graphite sealing ring | Graphite expands to seal at high temperature | All pressure classes |
According to the revised and released DL/T 1536-2025 "Guide for selection of power plant control valves", the following key points should be considered in control valve selection:
Control valves for steam and water systems in thermal power plants
Working pressure ≤ 45MPa
Working temperature ≤ 630°C
| Stage | Core Content |
|---|---|
| Structural type | Select single-seat, double-seat, cage, sleeve types based on conditions |
| Selection requirements | Flow characteristic, rangeability, Cv calculation, leakage class |
| Product selection | Material matching, actuator selection, accessory configuration |
| Site installation and commissioning | Installation position, pipe stress, commissioning procedures |
| Operation and maintenance | Maintenance intervals, common fault handling, spare parts management |
| Parameter | Power Plant Control Valve Requirement |
|---|---|
| Leakage class | Critical control valves require Class IV or higher |
| Rangeability | Typically 50:1 or higher |
| Flow characteristic | Equal percentage or linear, must match control system |
| Mistake | Correct Practice |
|---|---|
| Ignoring temperature effect on material strength | As temperature rises, allowable pressure decreases—select per ASME B16.34 or E101 pressure-temperature tables |
| Using soft seat valves in steam service | PTFE softens at high temperature—use metal-seated or graphite seals |
| Ignoring cavitation and flashing risks | Feedwater and desuperheating positions require anti-cavitation multi-stage pressure reducing design |
| Not verifying actuator response time | Bypass and ESD valves require ≤1-10 second response time |
| Using standard valves in frequent start/stop duty | Cyclic thermal stress causes fatigue failure—select valves designed for cycling service |
In gas-steam combined cycle power plants' heat recovery boiler water treatment systems, nuclear power auxiliary systems' demineralized water treatment, and biomass/waste-to-energy plants' condensate polishing, sanitary valves are beginning to find applications.
| Application Scenario | Sanitary Valve Type | Function |
|---|---|---|
| Chemical water treatment system | Sanitary butterfly valve, sanitary ball valve | Ultrapure water isolation, zero leakage |
| Demineralized water system | Sanitary diaphragm valve | Dead-leg-free, no contamination |
| Condensate polishing | Sanitary ball valve | Fast operation, low residue |
These applications typically operate at lower temperatures and pressures, but have extremely high requirements for cleanliness and leakage class. The design philosophy of sanitary valves aligns well with the high-purity water needs of power systems.
← Previous article: Valve in Petrochemical Applications: Refining and Chemical Plant Valve Configuration
→ Next article: Control Valve Selection Guide: Regulator Types, Flow Characteristics, and Sizing