With the 21 articles of this series now complete, readers frequently encounter specific questions in practical work. This article compiles the most common questions and answers, covering selection, installation, maintenance, materials, standards, and procurement – enabling quick reference when needed.
Answer: The valve pressure rating should be determined based on the system's maximum operating pressure and maximum operating temperature combined. ASME B16.34 provides pressure-temperature rating tables, with different materials having different allowable pressures at different temperatures. Selection should:
Determine the system's maximum operating temperature
Look up the material's maximum allowable working pressure at that temperature
Select a valve with pressure rating ≥ that value
Consider a safety margin (typically 10-15%)
Answer: Class 150 has an approximate working pressure of 19.6 bar (285 psi) at ambient temperature. However, Class is a rating level, not a fixed pressure value – the allowable pressure for the same Class varies at different temperatures. Always consult the pressure-temperature rating tables.
Answer:
| Feature | Gate Valve | Globe Valve |
|---|---|---|
| Primary function | Isolation (on/off) | Regulation/isolation |
| Flow resistance | Very low (fully open) | High |
| Sealing performance | Good | Excellent |
| Throttling capability | Poor (not recommended) | Excellent |
| Operating speed | Slow (multi-turn) | Slow (multi-turn) |
Selection principle: Choose gate valves for isolation with low pressure drop; choose globe valves for flow regulation.

Answer:
| Feature | Ball Valve | Butterfly Valve |
|---|---|---|
| Sealing performance | Excellent | Good |
| Size range | All sizes (floating ≤8") | Large diameter (≥DN50) |
| Pressure drop | Very low | Low |
| Cost | Higher | Lower (especially at large sizes) |
| Suitable media | Clean fluids | Water, gases, wastewater |
Selection principle: Choose ball valves for small diameters and tight shut-off; choose butterfly valves for large diameters and cost sensitivity.
Answer: Stainless steel is "stainless" because it forms a dense chromium oxide passive film on its surface. It can still rust or corrode under the following conditions:
Prolonged chloride exposure (e.g., saltwater, bleach) – pitting corrosion may occur
Mechanical damage to the passive film
Passive film breakdown at high temperatures
Contact with dissimilar metals (galvanic corrosion)
304 is susceptible to pitting in chloride environments – use 316L instead.
Answer: Follow these steps:
Identify the media: What chemical? What concentration?
Identify the temperature: Ambient or elevated?
Consult compatibility tables: Different materials have vastly different corrosion resistance to the same chemical
Consider cost: PTFE-lined valves are the most cost-effective solution for most corrosive media
Common recommendations:
Sulphuric acid → PTFE-lined or Alloy 20
Hydrochloric acid → PTFE-lined or rubber-lined (non-metallic preferred)
Nitric acid → 304 stainless steel (NOT 316L!)
Alkalis → Carbon steel (ambient) or special alloys (high temperature)
Chlorides/seawater → 316L stainless steel or duplex stainless steel
Answer: Key precautions include:
Correct flow direction: Install per the flow arrow on the valve body (uni-directional valves)
Stem upward: Generally recommended to install with stem vertical and upward
Avoid stress: Pipe supports should be independent; do not let the valve bear pipe weight
Keep clean: Remove weld slag and debris from piping before installation
Do not over-tighten: Tighten flange bolts evenly in star pattern – do not over-tighten
Do not use excessive force: Do not use the handwheel or actuator to lift the valve
Answer: Possible causes of internal leakage (flow still passing when closed):
Worn sealing surfaces: Need grinding or seat replacement
Debris on sealing surfaces: Disassemble and clean
Improper operation: Valve not fully closed
Aged seals: Replace seals
Excessive pressure: Exceeding valve pressure rating
Answer: Maintenance frequency depends on valve type, service conditions, and operating frequency:
Daily: Visual inspection (leakage, corrosion, abnormality)
Monthly: Check packing/bolts tightness
Quarterly: Inspect seals, cycle unused valves (prevent seizure)
Annually: Complete overhaul, calibration
Seal replacement: 1-3 years (depending on material and usage frequency)
Answer: The following signs indicate seal replacement is needed:
Cracking or hardening
Permanent deformation (loss of elasticity)
Visible wear or damage
Leakage when valve is closed
Reaching the recommended service life
Answer:
| Standard | Applicable Valves | Leakage Classes |
|---|---|---|
| API 598 | Isolation valves (gate, ball, butterfly, etc.) | Class A (bubble-tight), B, C |
| FCI 70-2 | Control valves (modulating) | Class I-VI (Class VI is highest) |
These apply to different valve types and should not be confused.
Answer: A fire-safe valve maintains sealing integrity during and after a fire. Design features include:
Anti-static devices
Fire-safe seats (soft seat melts, metal seat engages)
Spill-proof stem
Applications requiring fire-safe valves:
Flammable fluids (oil, natural gas, chemicals)
Refineries and petrochemical plants
Offshore platforms
Natural gas transmission pipelines
Applicable standards: API 607, API 6FA
Answer:
| Comparison | Pneumatic Actuator | Electric Actuator |
|---|---|---|
| Advantages | Fast response, explosion-proof, high torque | No air supply needed, precise control |
| Disadvantages | Requires compressed air | Slower response, poorer explosion-proof |
| Best for | Air supply available, hazardous areas | No air supply, precise control |
| ESD valves | Preferred (spring-return) | Not recommended (no auto-close on power loss) |
Answer: When fail-safe capability is required:
Fail Closed (FC): Valve automatically closes on air loss (e.g., burner fuel valve)
Fail Open (FO): Valve automatically opens on air loss (e.g., cooling water valve)
Spring-return is a unique feature of pneumatic actuators – electric actuators cannot auto-return on power loss.
Answer: Actuator torque should satisfy:
Actuator torque ≥ Valve operating torque × Safety factor
The safety factor is typically 1.2-1.5 (depending on media and conditions).
Methods to obtain valve operating torque:
Obtain from valve manufacturer (most accurate)
Refer to valve torque curves (break-to-open, running, end-to-open torque all differ)
Estimate independently (manufacturer data is recommended over self-calculation)
Answer: A complete technical specification should include:
Process parameters: Media, temperature, pressure, flow
Valve design parameters: Type, size, pressure rating, connection type, actuation
Material requirements: Body, trim, sealing materials
Design standards: Referenced standards with versions
Inspection and testing: Test types and standards
Certification requirements: Fire-safe, hygienic, explosion-proof, etc.
Documentation requirements: MTR, test reports, operation manuals
Answer: Evaluate from the following dimensions:
Technical capability: Design, manufacturing, technical team
Quality system: ISO 9001, inspection capability, testing equipment
Track record: Supply history for similar conditions
Delivery and capacity: Manufacturing lead time, capacity load
Commercial terms: Price, payment, after-sales service
Certifications: API, ASME, CE, FDA, etc.
Answer: Total Cost of Ownership includes:
Purchase cost (10-30%)
Installation cost (5-15%)
Operating energy (15-30%)
Maintenance cost (10-25%)
Downtime loss (10-20%)
Disposal cost (5-10%)
Importance: The initial purchase price may only account for 20-30% of total cost. A cheap valve with frequent repairs, high energy consumption, or early replacement may have a higher total cost than a more expensive valve.
Answer: Sanitary valves, designed for food, pharmaceutical, and biotech industries, feature:
Dead-leg-free design: No grooves or cavities (especially diaphragm valves)
Surface finish: Internal surfaces Ra ≤ 0.8 μm (Ra ≤ 0.4 μm for aseptic)
Material traceability: Complete MTRs and heat numbers
FDA compliance: Contact materials meet FDA 21 CFR
Cleanability: CIP/SIP compatible
Certifications: 3-A, EHEDG, ASME BPE
Answer:
| Feature | Sanitary Butterfly Valve | Sanitary Ball Valve |
|---|---|---|
| Primary function | Isolation (large diameter) | Isolation (small diameter, high purity) |
| Size range | DN25-DN300 | DN8-DN100 |
| Pressure drop | Low | Very low (full port) |
| CIP compatible | Excellent | Excellent |
| SIP compatible | Seat material dependent | Seat material dependent |
| Cost | Lower | Higher |
| Applications | CIP supply, large-diameter piping | High purity, small diameter, sampling |
Answer:
| Standard | Applicable Region | Focus |
|---|---|---|
| 3-A Sanitary Standards | USA | Dairy, food, pharmaceutical hygienic design |
| EHEDG | Europe | Hygienic engineering and design certification |
Both focus on hygienic design, but 3‑A originated from the US dairy industry, while EHEDG originated from European food engineering. Many international projects require both certifications.
Answer: NACE MR0175/ISO 15156 is the international standard for materials in sour service (H₂S) . In oil and gas, H₂S can cause sulphide stress cracking (SSC) . The standard specifies hardness limits and chemical composition requirements for metallic materials used in sour service. Not all stainless steels are suitable – NACE compliance must be explicitly specified.
Answer: DBB (Double Block and Bleed) means the valve isolates on both sealing surfaces simultaneously, with a bleed port between the two seals. DBB provides double isolation – even if one seal fails, the other still ensures isolation. DBB capability is a key advantage of trunnion-mounted ball valves; floating ball valves typically do not offer this feature.
Answer:
| Connection Type | Advantages | Applications |
|---|---|---|
| Flanged | Easy assembly/disassembly | Large diameter, high pressure, general industrial |
| Threaded | Low cost, fast installation | Small diameter, low pressure, general industrial |
| Welded | Zero leakage, permanent | Pharmaceutical, high purity, permanent installation |
| Tri-clamp | Quick disassembly, hygienic | Food, pharmaceutical, sanitary |