With the 21 articles of this series now complete, readers frequently encounter specific questions in practical work. This article compiles the most common questions and answers, covering selection, installation, maintenance, materials, standards, and procurement – enabling quick reference when needed.

1. General Selection Questions

1. How do I determine the valve's pressure rating?

Answer: The valve pressure rating should be determined based on the system's maximum operating pressure and maximum operating temperature combined. ASME B16.34 provides pressure-temperature rating tables, with different materials having different allowable pressures at different temperatures. Selection should:

  1. Determine the system's maximum operating temperature

  2. Look up the material's maximum allowable working pressure at that temperature

  3. Select a valve with pressure rating ≥ that value

  4. Consider a safety margin (typically 10-15%)

2. What is Class 150 in bar?

Answer: Class 150 has an approximate working pressure of 19.6 bar (285 psi) at ambient temperature. However, Class is a rating level, not a fixed pressure value – the allowable pressure for the same Class varies at different temperatures. Always consult the pressure-temperature rating tables.

3. What is the difference between gate and globe valves? How to choose?

Answer:

FeatureGate ValveGlobe Valve
Primary functionIsolation (on/off)Regulation/isolation
Flow resistanceVery low (fully open)High
Sealing performanceGoodExcellent
Throttling capabilityPoor (not recommended)Excellent
Operating speedSlow (multi-turn)Slow (multi-turn)

Selection principle: Choose gate valves for isolation with low pressure drop; choose globe valves for flow regulation.

Sanitary Flexible Impeller Pump Construction.jpg

4. What is the difference between ball and butterfly valves? How to choose?

Answer:

FeatureBall ValveButterfly Valve
Sealing performanceExcellentGood
Size rangeAll sizes (floating ≤8")Large diameter (≥DN50)
Pressure dropVery lowLow
CostHigherLower (especially at large sizes)
Suitable mediaClean fluidsWater, gases, wastewater

Selection principle: Choose ball valves for small diameters and tight shut-off; choose butterfly valves for large diameters and cost sensitivity.

2. Materials and Corrosion

5. Can stainless steel valves rust?

Answer: Stainless steel is "stainless" because it forms a dense chromium oxide passive film on its surface. It can still rust or corrode under the following conditions:

  • Prolonged chloride exposure (e.g., saltwater, bleach) – pitting corrosion may occur

  • Mechanical damage to the passive film

  • Passive film breakdown at high temperatures

  • Contact with dissimilar metals (galvanic corrosion)

304 is susceptible to pitting in chloride environments – use 316L instead.

6. How do I select corrosion-resistant valve materials?

Answer: Follow these steps:

  1. Identify the media: What chemical? What concentration?

  2. Identify the temperature: Ambient or elevated?

  3. Consult compatibility tables: Different materials have vastly different corrosion resistance to the same chemical

  4. Consider cost: PTFE-lined valves are the most cost-effective solution for most corrosive media

Common recommendations:

  • Sulphuric acid → PTFE-lined or Alloy 20

  • Hydrochloric acid → PTFE-lined or rubber-lined (non-metallic preferred)

  • Nitric acid → 304 stainless steel (NOT 316L!)

  • Alkalis → Carbon steel (ambient) or special alloys (high temperature)

  • Chlorides/seawater → 316L stainless steel or duplex stainless steel

3. Installation and Maintenance

7. What should I pay attention to when installing valves?

Answer: Key precautions include:

  1. Correct flow direction: Install per the flow arrow on the valve body (uni-directional valves)

  2. Stem upward: Generally recommended to install with stem vertical and upward

  3. Avoid stress: Pipe supports should be independent; do not let the valve bear pipe weight

  4. Keep clean: Remove weld slag and debris from piping before installation

  5. Do not over-tighten: Tighten flange bolts evenly in star pattern – do not over-tighten

  6. Do not use excessive force: Do not use the handwheel or actuator to lift the valve

8. What should I do if a valve has internal leakage?

Answer: Possible causes of internal leakage (flow still passing when closed):

  1. Worn sealing surfaces: Need grinding or seat replacement

  2. Debris on sealing surfaces: Disassemble and clean

  3. Improper operation: Valve not fully closed

  4. Aged seals: Replace seals

  5. Excessive pressure: Exceeding valve pressure rating

9. How often should valves be maintained?

Answer: Maintenance frequency depends on valve type, service conditions, and operating frequency:

  • Daily: Visual inspection (leakage, corrosion, abnormality)

  • Monthly: Check packing/bolts tightness

  • Quarterly: Inspect seals, cycle unused valves (prevent seizure)

  • Annually: Complete overhaul, calibration

  • Seal replacement: 1-3 years (depending on material and usage frequency)

10. How do I know when seals need replacement?

Answer: The following signs indicate seal replacement is needed:

  • Cracking or hardening

  • Permanent deformation (loss of elasticity)

  • Visible wear or damage

  • Leakage when valve is closed

  • Reaching the recommended service life

4. Standards and Certifications

11. What is the difference between API 598 and FCI 70-2?

Answer:

StandardApplicable ValvesLeakage Classes
API 598Isolation valves (gate, ball, butterfly, etc.)Class A (bubble-tight), B, C
FCI 70-2Control valves (modulating)Class I-VI (Class VI is highest)

These apply to different valve types and should not be confused.

12. What is a fire-safe valve? When is it required?

Answer: A fire-safe valve maintains sealing integrity during and after a fire. Design features include:

  • Anti-static devices

  • Fire-safe seats (soft seat melts, metal seat engages)

  • Spill-proof stem

Applications requiring fire-safe valves:

  • Flammable fluids (oil, natural gas, chemicals)

  • Refineries and petrochemical plants

  • Offshore platforms

  • Natural gas transmission pipelines

Applicable standards: API 607, API 6FA

5. Actuators

13. How do I choose between pneumatic and electric actuators?

Answer:

ComparisonPneumatic ActuatorElectric Actuator
AdvantagesFast response, explosion-proof, high torqueNo air supply needed, precise control
DisadvantagesRequires compressed airSlower response, poorer explosion-proof
Best forAir supply available, hazardous areasNo air supply, precise control
ESD valvesPreferred (spring-return)Not recommended (no auto-close on power loss)

14. When is a spring-return actuator required?

Answer: When fail-safe capability is required:

  • Fail Closed (FC): Valve automatically closes on air loss (e.g., burner fuel valve)

  • Fail Open (FO): Valve automatically opens on air loss (e.g., cooling water valve)

Spring-return is a unique feature of pneumatic actuators – electric actuators cannot auto-return on power loss.

15. How do I calculate actuator torque?

Answer: Actuator torque should satisfy:
Actuator torque ≥ Valve operating torque × Safety factor

The safety factor is typically 1.2-1.5 (depending on media and conditions).

Methods to obtain valve operating torque:

  1. Obtain from valve manufacturer (most accurate)

  2. Refer to valve torque curves (break-to-open, running, end-to-open torque all differ)

  3. Estimate independently (manufacturer data is recommended over self-calculation)

6. Procurement and Supply Chain

16. How do I write a valve technical specification?

Answer: A complete technical specification should include:

  1. Process parameters: Media, temperature, pressure, flow

  2. Valve design parameters: Type, size, pressure rating, connection type, actuation

  3. Material requirements: Body, trim, sealing materials

  4. Design standards: Referenced standards with versions

  5. Inspection and testing: Test types and standards

  6. Certification requirements: Fire-safe, hygienic, explosion-proof, etc.

  7. Documentation requirements: MTR, test reports, operation manuals

17. How do I evaluate valve suppliers?

Answer: Evaluate from the following dimensions:

  1. Technical capability: Design, manufacturing, technical team

  2. Quality system: ISO 9001, inspection capability, testing equipment

  3. Track record: Supply history for similar conditions

  4. Delivery and capacity: Manufacturing lead time, capacity load

  5. Commercial terms: Price, payment, after-sales service

  6. Certifications: API, ASME, CE, FDA, etc.

18. What is Total Cost of Ownership (TCO) and why is it important?

Answer: Total Cost of Ownership includes:

  • Purchase cost (10-30%)

  • Installation cost (5-15%)

  • Operating energy (15-30%)

  • Maintenance cost (10-25%)

  • Downtime loss (10-20%)

  • Disposal cost (5-10%)

Importance: The initial purchase price may only account for 20-30% of total cost. A cheap valve with frequent repairs, high energy consumption, or early replacement may have a higher total cost than a more expensive valve.

7. Sanitary Valves

19. What is the difference between sanitary and standard valves?

Answer: Sanitary valves, designed for food, pharmaceutical, and biotech industries, feature:

  • Dead-leg-free design: No grooves or cavities (especially diaphragm valves)

  • Surface finish: Internal surfaces Ra ≤ 0.8 μm (Ra ≤ 0.4 μm for aseptic)

  • Material traceability: Complete MTRs and heat numbers

  • FDA compliance: Contact materials meet FDA 21 CFR

  • Cleanability: CIP/SIP compatible

  • Certifications: 3-A, EHEDG, ASME BPE

20. How do I choose between Sanitary Butterfly Valve and Sanitary Ball Valve?

Answer:

FeatureSanitary Butterfly ValveSanitary Ball Valve
Primary functionIsolation (large diameter)Isolation (small diameter, high purity)
Size rangeDN25-DN300DN8-DN100
Pressure dropLowVery low (full port)
CIP compatibleExcellentExcellent
SIP compatibleSeat material dependentSeat material dependent
CostLowerHigher
ApplicationsCIP supply, large-diameter pipingHigh purity, small diameter, sampling

21. What is the difference between 3-A and EHEDG?

Answer:

StandardApplicable RegionFocus
3-A Sanitary StandardsUSADairy, food, pharmaceutical hygienic design
EHEDGEuropeHygienic engineering and design certification

Both focus on hygienic design, but 3‑A originated from the US dairy industry, while EHEDG originated from European food engineering. Many international projects require both certifications.

8. Other Common Questions

22. What is NACE MR0175?

Answer: NACE MR0175/ISO 15156 is the international standard for materials in sour service (H₂S) . In oil and gas, H₂S can cause sulphide stress cracking (SSC) . The standard specifies hardness limits and chemical composition requirements for metallic materials used in sour service. Not all stainless steels are suitable – NACE compliance must be explicitly specified.

23. What is DBB (Double Block and Bleed)?

Answer: DBB (Double Block and Bleed) means the valve isolates on both sealing surfaces simultaneously, with a bleed port between the two seals. DBB provides double isolation – even if one seal fails, the other still ensures isolation. DBB capability is a key advantage of trunnion-mounted ball valves; floating ball valves typically do not offer this feature.

24. How do I choose the valve connection type?

Answer:

Connection TypeAdvantagesApplications
FlangedEasy assembly/disassemblyLarge diameter, high pressure, general industrial
ThreadedLow cost, fast installationSmall diameter, low pressure, general industrial
WeldedZero leakage, permanentPharmaceutical, high purity, permanent installation
Tri-clampQuick disassembly, hygienicFood, pharmaceutical, sanitary